How to Read Last Sale During a Power Failure

If an A.C. power failure occurs, the dispenser will display the last sale in progress at the
time of the failure. This display will alternate with the "Power Fail Message" (PPPPPP).
This will continue for 15 minutes after the dispenser has lost power. If power is returned,
the display will go back to it's normal display.
NOTE: The battery will display data for 15 minutes.
Example : The customer is dispensing fuel and the dispenser / site loses power. The
customer has pumped $7.50 to this point. See Figure 1. At this point the dispenser valve
closes and the customer cannot continue fueling. The display will continue to alternate
between showing the amount (along with the volume amount) and the Power Fail mes-
sage for 15 minutes. After the 15 minutes if power is still out, the display goes blank
until power is returned.

HOW TO PREPARE THE DISPENSER FOR PROGRAMMING

NOTE: When a control console is used, some of the functions can be programmed and are downloaded to
the dispenser from the console. Examples are maximum delivery, slow flow offset and prices etc.
Connecting the Manager's keypad for dispenser programming.
Programming is done from the manager's keypad located inside the electronics compart-
ment. If the dispenser was ordered with the Local Preset option, you will use the Local
Preset keypad to program the dispenser. The following example assumes using the Man-
ager Keypad.
To enable the dispenser for programming:
1.
Remove the keypad and cable from the plastic bag located on the inside of the elec-
tronic enclosure. Connect the cable to the Manager Keypad.
2.
Locate the keypad receptacle located on the back of the CPU board, which is located
on the backside of the electronic door (If you have the Local Preset option the Local
Preset board will already be plugged in to the CPU). The plug receptacle is labeled
"J3" and is located on the right side edge of the CPU if viewed with the electronics
door open and from the back side of the board. (See Figure 3). This is where the
Manager Keypad and cable will connect to the CPU to program that hose.
Note—There is one CPU per hose. The CPU board has a black switch on top. See Figure
4.
Note- Make sure the handle is hung up in the dispenser nozzle boot.
3.
With the dispenser power on, plug the manager's keypad and cable into the con
nector labeled J3 on the CPU board.
3000 Series Retail Operators Manual 108796 Rev C, 07/05
16
Fig. 1
Fig. 2
Fig. 3 - Manager Keypad
Fig. 4 - Plugging the manager keypad
into the J3 connection.