Little Squirt 3k Electronic Dispensers Specification Sheet
Commercial/Industrial volume display or Retail, money & volume display
Standard Features
Simple electronic computer
Stand-alone or Interfaced to Control Device
Retail Version: RS485 interface or current
loop or dual pulse output
Commercial/Industrial Version: RS485 inter-
face or dual pulse output
TM
Exclusive eCal
(Electronic Calibration)
Magnet activated totals display
Programmable unit of measure for US gal-
lons, liters, or imperial gallons
Operates from 115/230Vac, 60/50Hz, or 380
Vac, 50Hz
Back lit LCD displays
Satellite Outlet Connection
Remote or Suction models available
Single Master, dual master, or master/
satellite combination for Remote models
Single Master for Suction models
Field configurable for single point or simulta-
neous master & satellite fueling
Construction
Low Hose Cabinet Design or
High Hose Cabinet Design
Front or side mount nozzle boots
Heavy duty lift-to-start nozzle boots
Long-life cabinet construction using gal-
vaneal components and powder coated pan-
els
Black end panels & top
Black dial face covers
Green lower doors (optional colors available)
Hinged swing out lower door
Hinged swing down upper door
Heavy duty hose hook or retractors depend-
ing upon model
Computer
Simple single board design electronics.
Includes CPU, power, display, eCal, RS485
or current loop connection, electromechanical
analog totalizer, push-button programming
switches, wiring terminal strip
LED Backlighting board for the LCD display
Optical pulser
Designed for temperature extremes—no
heaters or cooling fans required
Long life, highly visible back lit LCD display,
1" (2.54cm) numerals for money & volume;
1/2" (1.27cm) numerals for price-per-volume
Battery Backup for last sale recall during
power outage (required for resale of fuel)
Bennett Commercial Pump Company & Bennett Pump Company ~ 1218 E. Pontaluna Rd. ~ Spring Lake, Mi, USA 49456 ~
tel: 231-798-1310 ~ USA Bid & Spec Desk 800-235-7618 ~ fax: 231-799-6202 ~ sales@bennettpump.com ~ www.bennettpump.com ~
www.bennettusa.com
3000 Series Retail Operators Manual 108796 Rev C, 07/05
6
Computer (cont'd)
Simple 2-command protocol via RS485 inter-
face to fleet management systems supplies
pump status, pulses, volume sale and vol-
ume totals
Current loop Bennett fuel protocol interface
for Retail Versions only
Field wiring goes directly to terminal strip on
Computer (for new installations pull 72" of
wire above grade level)
Transaction display of: 999.999 for gallons,
9999.99 for liters and 6-digits for money with
programmable decimal point
Electronic hose totals of:
99999999.999 for gallons (8.3)
999999999.99 for liters (9.2)
Built-in diagnostics with error codes
Hydraulics
Rotary meter rated at 70gpm maximum
1" 2-Stage prepay/preset electric solenoid
valve for Remote models (optional on Suction
models)
Built-in inlet check valves to keep the hydrau-
lics full and prevent meter/pulser count-up
when the submersible pump pressurizes the
system
Metal Y-strainer
1" elbow hose outlet(s)
1-1/2" ground joint union inlet
Options
Programmable Dual Pulse Output Board to
interface to fleet management systems &
tank monitoring system if RS485 is not used
1" 2-Stage prepay/preset electric solenoid
valve for 1-product, 1-hose Suction model.
(valve is standard on all other models)
Subpump relay 3-phase contactor
Intercom speaker for high hose models
Explosion proof junction box for lower hy-
draulic area
Brushed stainless steel lower doors
Brushed stainless end panels
Custom lower door colors and/or graphics
Hoses, nozzles, swivels
Satellite-in-use light
Satellites (requires satellite board in master.
Order from service parts)
For information on flow rates, motor
sizes, and model configurations see
our Model Configuration Chart &
Specification Sheet
TM
UL
listed
Certified for resale applications. The
N.T.E.P. Certificate of Conformance is
available upon request
Units have been tested and found to
comply with the limits for a Class A
computing device in accordance with
Subpart J of Part 15 of FCC Rules re-
garding radio frequency interference.
Specifications in this document are
subject to change without notice.