Default Programming Settings - Bennett 3000 Series Operator's Manual

Retail dispensers with 210 electronics
Hide thumbs Also See for 3000 Series:
Table of Contents

Advertisement

The software program for each new dispenser shipped from the factory is preprogrammed with default settings in
some of the Menu Codes. Some menu codes must be changed immediately to make the dispenser operational in
your situation. See Initial Setup Sequence below. For your convenience, the default listings are noted below:
Menu Code
0
Diagnostics
1
Money and Volume Totals
3
Manager Access
4
Prices
8
Decimal Location
9
No Flow Time Out
10
Slow Flow Amount
11
Volume Allocation
12
Prestart Time
15
Fleet Option
16
Unit Volume
17
Local Preset
18
Motor Delay
21
Stand Alone
22
Dispenser Address
24
Preset Data Entry Digit Pointers
27
Meter Calibration
83
Cold Start
99
Volume Units
To program the dispensers memory for the first time, or following a RAM memory clear follow the menu codes in
the order that they appear in the "Initial Setup" sequence below. If not, the dispenser may not operate properly
because of default settings.
The menu codes are explained in the Operators Manual in numerical order.
Menu
Code No.
Manager Access Code
3
Unit of Measurement
99
Pricing
4
9
No Flow Time out
11
Volume Allocation for a sale at a pump
Current Loop, Stand Alone or RS485 mode
21
3000 Series Retail Operators Manual 108796 Rev C, 07/05
DEFAULT SETTINGS
Suggested Start Up Sequence
INITIAL SETUP
18
Description Default
2218
0000
0 = U.S.A.
- - - = Infinite Time
0.100 Volume Unit
9999 Volume Units
2 seconds
1 = Enabled
0 = Disabled
2 Seconds
Current Loop
0 = Program to set the dispenser address.
Off
0.00
Program to set the dispenser at gallon or liter operation.
Menu
REMAINING DISPENSER SETUP
Code No.
8
Decimal Location - for other than U.S. standard
10
Slow Flow Amount - control for prepay sales
Precharge Time - for submerged pump
12
Fleet System - Interface compatibility
15
17
Local Preset - operation
18
Motor Delay - Self Contained Pumps
Dispenser Address
22
27
Meter Calibration—View Only

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3824381138123822

Table of Contents