Menu Code 17 - How To Set The Local Preset Option - Bennett 3000 Series Operator's Manual

Retail dispensers with 210 electronics
Hide thumbs Also See for 3000 Series:
Table of Contents

Advertisement

Menu Code 17 - How to Program the Local Preset Option
This menu code tells the dispenser whether the optional local preset keypad is installed on the dis-
penser.
NOTE: If no local preset key pad is installed on the dispenser, do not enter this menu code to
change the setting. The default setting is for no local preset.
This menu code also tells the dispenser how to operate the local preset option. The options are:
0 - No Local preset keypad. See Figure 1
1 - Local preset installed; customer can select a money amount only. See Figure 2
2 - Local preset installed; customer can select a volume amount only. See Figure 3
3 - Local preset installed; customer can select a volume amount or a money amount. See
Figure 4.
To select a different option in Menu Code 17, follow this procedure:
1. After the Manager's Mode has been accessed, press the number 1 and 7, then the MODE button
on the keypad. The PPV display shows the dispenser is in Menu Code 17.
If the dispenser has not been programmed since it came from the factory, the number 0 appears in
the main display. See Figure 1. This is the default setting.
2. To change the setting, use the 0 through 3 buttons on the keypad to enter a new option.
NOTE: If an error is made, press the correct number. The new number replaces the error.
3. When the correct option number appears in the volume display, press the ENTER button to save
the selection.
4. Press the CANCEL button to exit this menu code.
3000 Series Retail Operators Manual 108796 Rev C, 07/05
28
Fig. 1
Fig. 2
Fig. 3