This manual contains installation instructions for installing the Pacific eNVy Series dispenser. Included are mechanical,
transporting, wiring, and start-up instructions. Please refer to the original manufacturer's installation instructions for
proper installation on underground liquid storage systems, shear valves, hoses, and breakaways.

Related Documents

Bennett 515 Pump Controller Installation & Service Manual ---------------------------------------------Part# 105022
Bennett Pacific eNVy Series Operators Manual -----------------------------------------------------------Part# 128503
Bennett Pacific eNVy Series Parts Manual ----------------------------------------------------------------Part# 128504
Pacific eNVy Maintenance Schedule and Log -------------------------------------------------------------Part# 130886
Pacific eNVy Series Audit Report -------------------------------------------------------------------------Part# 112827
Simply Secure Payment PCI 3.1 (SSP Color) Programming, Service, and Part Manual ------------------Part# 124184
Simply Secure Payment PCI 3.1 (SSP Large Display) Programming, Service, and Parts Manual --------Part# 128203
Simply Secure Payment (SSP Large Display w/ SBC2) Programming, Service, and Parts Manual -------Part #132544

Power Requirements

AC Power Input, Electronic ..........................................................................................................120/240 VAC, 50/60 Hz. 350 Watts Max.
DC Power Supply Output ....................................................................................................................................... +12 VDC at 2.0 Amps Max.
Lead-Acid Battery Output ...................................................................................................................................... +12 VDC at 5.0 Amp Hours
Nickel-Cadmium Battery Output .............................................................................................................. +3.6 VDC at 250 Milliamp Hours

Environmental Requirements

Operating Temperature Range ............................................................................................................. -40°C to +65°C (-40°F to +150°F)
Humidity ............................................................................................................................................................................... 0-95% non-condensing

Dimensions

1000 eNVy Series Maximum ................................................................................................... * 49" (width) x 22" (depth) x 91" (height)
1000 eNVy Series Base ................................................................................................................... 43
1000 Extended Blender Series Maximum .......................................................................... * 65" (width) x 22" (depth) x 90" (height)
1000 Extended Blender Series Base ................................................................................... 52
1000 Series Estimated Shipping Weight ..........................................................................................................650 pounds/295 kilograms

Codes and Standards

NFPA 30 – Flammable and Combustible Liquids Code
NFPA 30A – Code for Motor Fuel Dispensing Facilities and Repair Garages
NFPA 70 – National Electric Code®
ASME B31.3 – Process Piping
International Fire Code – 2000 Edition

Introduction

1
+24 VDC at 2.0 Amps Max.
*without valance
3
/
" (width) x 15
" (depth) -
1
/
8
8
44 ½" (width) x 19 ¼" (depth) -
*without valance
3
/
" (width) x 14
13
/
" (depth) -
16
16
52
5
/
" (width) x 20
5
/
" (depth) -
8
16
Introduction