How To Program The Mechanical Pulse Output - Bennett 3000 Series Operator's Manual

Retail dispensers with 210 electronics
Hide thumbs Also See for 3000 Series:
Table of Contents

Advertisement

37

How to Program the Mechanical Pulse Output

There is no menu code for pulse output on the 3000 series dispenser. Instead, a Pulse Output board is used that allows the
dispenser to be connected to a Fleet System like a mechanical dispenser. The dispenser will generate pulse and handle
signals to the Fleet System. There are jumpers on this Pulse Output Board which determine what the pulse rate will be and
what the pulse width will be. This Pulse Output board is capable of sending out pulses at the following ratios:
1:1
10:1
100:1
1000:1
Also, the pulse width selections can be set with jumpers for selections as follows:
.5 milliseconds
1 millisecond
2 millisecond
4 millisecond
8 millisecond
16 millisecond
32 millisecond
64 millisecond
Also, when using a Pulse Output board, the dispenser should be programmed for RS485 communication (mode 21).
See the information on the following page that describes how to set up the Pulse Output Board for use with a 3rd party
Fleet System.
3000 Series Retail Operators Manual 108796 Rev C, 07/05

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3824381138123822

Table of Contents