Menu Code 9 - How To Set A No Flow Timeout - Bennett 3000 Series Operator's Manual

Retail dispensers with 210 electronics
Hide thumbs Also See for 3000 Series:
Table of Contents

Advertisement

Menu Code 9 - How to Set a No Flow Time Out
As a safety feature, the dispenser can be programmed to turn off if no flow occurs for a specific
amount of time. If the pump handle is turned on, but no flow occurs, the No Flow Time Out fea-
ture prevents delivery after the amount of time that you program. If the pump handle is turned on
and flow occurs, but is stopped, the No Flow Time Out feature prevents delivery after the amount
of time programmed has elapsed. If a no flow timeout is set and is reached, the valve in the dis-
penser automatically closes preventing further fueling for that transaction.
The No Flow Time Out feature is programmable from 0 seconds to 999 seconds. An entry of 0 =
infinite time that will be displayed as "---". The dispenser is shipped from the factory with Menu
Code 9 disabled (infinite time (all dashes)).
To program an amount of time before the No Flow Time Out turns off the dispenser or to disable
Menu Code 9, follow this procedure:
1. After the Manager's Mode has been accessed, press the 9 button and then the MODE button
on the keypad. See Figure 1. The default is infinite time. The PPV display shows the dis-
penser is in Menu Code 9. See Figure 2.
The three dashes mean the No Flow Time Out amount is an infinite amount or that Menu Code
9 is disabled. The main solenoid valve and the slow flow valve remain on after the pump han-
dle lever is put in the ON position and the dispenser is authorized.
2. Use the 0 through 9 buttons on the keypad to enter a Flow Time Out value in seconds. For
example, if a 10 second delay is entered, the volume display window looks like Figure 3.
3. Use the 0 through 9 buttons on the keypad to enter a Flow Time Out value in seconds. For
example, if a 20 second delay is entered, the volume display window looks like Figure 4.
NOTE: If an error is made, press the 0 button until all three digits are zeros and enter a
new number, or push number buttons until the correct number of seconds appears in the
volume display.
4. When the correct value appears in the volume display, press the ENTER button to save the
selection.
5. To disable Menu Code 9, press the 0 button on the keypad and press the ENTER button. The
volume display returns to three dashes. See Figure 5.
6. Press the CANCEL button to exit this menu code.
3000 Series Retail Operators Manual 108796 Rev C, 07/05
23
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3824381138123822

Table of Contents