6.3 OPERATOR MAINTENANCE

Lubrication

Hydraulic Oil (HO)
HYDRAULIC SYSTEM OPERATING
TEMPERATURE RANGE
+0° F to +180° F (-18° C to -83° C)
+0° F to +210° F (-18° C to +99° C)
+50° F to +210° F (+10° C to +99° C)
NOTE: Hydraulic oils must have anti-wear qualities at least to API
Service Classification GL-3, and sufficient chemical stabil-
ity for mobile hydraulic system service.
NOTE: Aside from JLG recommendations, it is not advisable to
mix oils of different brands or types, as they may not con-
tain the same required additives or be of comparable vis-
cosities.
The hydraulic oil level in the pump reservoir can vary with oil
temperature (i.e., the oil level in a cold machine may not be up
to the FULL line on the dipstick). Cycle the mast up and down
a few times to get a more accurate reading on the dipstick.
Once the hydraulic oil is warmed, check the dipstick reading.
31215821
SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE
NOTE: If hydraulic oil is to be added, CHECK THE HYDRAULIC OIL
SAE VISCOSITYGRADE
10W
10W-20, 10W-30
20W-20
It should be up to or close to the FULL line on the dipstick.
• DO NOT FILL PAST THE FULL LINE.
• ALWAYS ADD oil if level is at or below the ADD line.
DECAL located on the right side frame, opposite the pump
assembly, for hydraulic oil type and specification. DO NOT
OVERFILL.
The hydraulic oil level in the
reservoir located on the
hydraulic pump assembly
should read to or close to
the FULL LINE on the
Hydraulic Reservoir dip stick
when hydraulic oil is at
operating temperature.
6-5