SECTION 3 - MACHINE OPERATION
3.6

BATTERY CHARGING

Battery Low Voltage Warning Indicators

The Platform Control Console and Ground Control Station indicate battery low voltage at three Warning Levels.
WARNING
LEVEL
PLATFORM CONTROL LED
LEVEL 1
LEVEL 2
LEVEL 3
NOTE:
To maximize battery life, it is recommended that the factory supplied batteries be charged continuously for a minimum of four hours or until eight bars are lit on the ground station LCD
Display before operating the machine. When drained to Warning Level 2 or 3, batteries must be charged until eight bars are lit on the ground station LCD display to clear the fault code.
3-6
Table 3-1. Battery Low Voltage Warning Indicators
INDICATOR LOCATION
GROUND CONTROL LCD
RESULT
• 3 LEDs/BARS Flashing with an
audible beep.
• Machine will Operate - No Control
Functions Locked Out.
• 2 LEDs/BARS Flashing with an
audible beep.
• Platform Lift-UP Function is Locked
Out.
• 1 LED/BAR Flashing with an audible
beep.
• Drive and Platform Lift-UP
Functions Locked Out.
ACTION REQUIRED
TO CLEAR FAULT
Charge batteries to a level of four LEDs/
BARS or more before operating.
Charge batteries for a minimum of four
continuous hours or eight LEDs/BARS lit
before operating. (Refer to note.)
Charge batteries for a minimum of four
continuous hours or eight LEDs/BARS lit
before operating. (Refer to note.)