Activating Programming Mode - JLG 10MSP Operation And Safety Manual

Table of Contents

Advertisement

SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE

Activating Programming Mode

NOTE: If machine does not power up, check that both the Ground
Control Station - Emergency Stop Button, and the Plat-
form Control Console - Emergency Stop Button, are in the
RESET position.
Also if machine is equipped with the (PSL) Programmable
Security Lock option, see Section 3 of this Operators Man-
ual for additional machine power-up steps.
6-16
Activating Programming Mode
1. With machine power OFF, press and hold the Brake Release Button (1) on the
Ground Control Station.
2. While holding the Brake Release Button in, power machine up by turning the
Main Power Selector Switch (2), to either the Ground Control or Platform Con-
trol Mode.
3. Release the Brake Release Button (1) after machine is powered up. The LCD
display should now display five zeros, one with a box around. Continue to next
step Entering Password.