JLG 10MSP Operation And Safety Manual page 42

Table of Contents

Advertisement

voltage is low (below 104VAC), then the charging
power will be reduced to avoid high input currents. If
the ambient temperature is too high, then the
charging power will also be reduced to maintain a
maximum internal temperature.
3.
When the GREEN 'CHARGED' LED turns on, the batter-
ies are completely charged.
-
+
-
+
The charger may now be unplugged from AC power
(always pull on plug and not cord to reduce risk of
damage to the cord). If left plugged in, the charger will
automatically restart a complete charge cycle if the
battery pack voltage drops below a minimum voltage
or 30 days has elapsed.
31215821
CHARGE COMPLETE
GREEN (TOP) LED ON
100% Complete
SECTION 3 - MACHINE OPERATION
4.
If a fault occurred anytime during charging, a fault
indication is given by flashing the RED 'FAULT' LED
with a code corresponding to the error.
-
+
-
+
See Flash Codes following
There are several possible conditions that generate
errors. Some errors are serious and require human
intervention to first resolve the problem and then to
reset the charger by interrupting AC power for at least
10 seconds. Others may be simply transient and will
automatically recover when the fault condition is elim-
inated. To indicate which error occurred, the RED
'FAULT' LED will flash a number of times, pause, and
then repeat.
CHARGING PROBLEM
RED (BOTTOM) LED ON
3-9

Hide quick links: