• Platform
Enable, and Left Hand Lift Enable - The
machine will not operate (drive or lift) unless
all these switches are pressed and held during
drive or lift operation. A timeout will occur
after five seconds if enable is engaged and no
function is selected.
d. Raise and lower platform 2 ft to 3 ft (0.61 m to 0.92 m)
several times. Check for smooth lifting and lowering of
platform.
• When the platform is elevated, visually inspect
the mast sections, slide pads, mast chains,
sequencing cables, platform control and
power cables (on side of mast). Ensure power
cables are properly tensioned and seated in
sheaves and rotating freely.
Platform
di.
Machines Only) - If the machine is equipped with
a Platform Gate Alarm, an alarm will sound and all
lifting and driving functions will stop if either or
both gates are opened once the platform is raised
approximately 1 in above the fully stowed posi-
tion.
31215821
Joystick
Enable,
Footswitch
Gate
Open
(Australian
SECTION 2 - PREPARATION AND INSPECTION
NOTE: (Australian Spec machines also include a platform gate
lock/release lever mechanism on top of each gate that
must be pressed down to open the platform gate. Check
that the lock/release on each gate latches properly when
gate is closed and releases when the handle lever is
depressed.)
Spec.
Platform Gate Lock/Release Lever
(Australian Spec. Machines Only)