In the LCD Display Symbols (refer to Figure 3-6., item 2), the
Function Display or Function Disabled Indicators will vary as
shown following:
31215821
DRIVE Disabled
LIFT UP Disabled
LIFT DOWN Disabled
Both LIFT UP and LIFT DOWN Disabled
Drive Speed Cut-Back (Turtle) Mode
Engaged (When Platform is Elevated)
Battery Charger (AC) Plugged In
SECTION 3 - MACHINE OPERATION

Tilt Alarm Warning

The Ground Control Station LCD screen flashes a fault code
and gives an audible warning. The LEDs on the platform con-
trol console also flash during tilt warning. Refer to Table 3-2.
THE GROUND CONTROL STATION CONTAINS A 1.5 DEGREE TILT ALARM. IF
THE TILT ALARM HAS BEEN ACTIVATED, THE PLATFORM WILL NOT ELEVATE.
ALSO IF THE TILT ALARM HAS BEEN ACTIVATED WHEN THE PLATFORM IS ELE-
VATED, THE DRIVE AND LIFT UP FUNCTIONS WILL BE DISABLED UNTIL THE
PLATFORM IS COMPLETELY LOWERED AND DRIVEN OFF THE TILT CONDITION.

LCD Display Fault Conditions

Table 3-2 following shows common LCD display fault indicators
which may occur during operation and are usually caused by
either an error in machine operation or a work area condition.
These fault conditions can usually be corrected by the operator
and do not require a qualified mechanic to repair:
AFTER A FAULT CONDITION IS CORRECTED THE MACHINE POWER MAY NEED
TO BE RECYCLED TO RESET THE GROUND CONTROL STATION.
3-15