7.2
MACHINE CONFIGURATION PROGRAMMING
INFORMATION
NOTE: When configuring an 1230ES machine, the machine
configuration must be completed before any person-
ality settings can be changed. Changing the person-
Configuration
Setting
Digit
Range
0
1
1
2
(Model #)
3
4
5
0
1
2
2
3
(Market)
4
5
3
0
(Tilt Cutout)
1
4
0
(Drive Cutout)
1
5
0
(Charger
1
Interlock)
0
6
1
(Ground Alarm)
2
0
1
7
(Load)
2
8
0
(Drive Motors)
1
0
9
(Elev. Prox.)
1
0
10
(Battery)
1
0
11
(Footswitch)
1
3121222
Table 7-1. Machine Configuration Programming Information (4150473-F)
Machines Equipped with Sevcon (1600346) Power Module ONLY
1230ES
1930ES
2030ES
2630ES
2646ES
3246ES
ANSI USA
ANSI EXPORT
CSA
CE
AUSTRALIA
JAPAN
NO - Drive and lift up NOT PREVENTED while tilted (Ground and Platform Mode).
YES - Drive and lift up PREVENTED while tilted (Ground and Platform Mode).
NO - Drive and lift up NOT PREVENTED while elevated.
YES - Drive and lift up PREVENTED while elevated.
DRIVE ONLY - Drive motion PREVENTED while vehicle is charging.
DRIVE AND LIFT UP - Drive and lift up motions ARE PREVENTED while vehicle is charging.
Required for CE.
NOT INSTALLED - Vehicle alarm will function for Arm Guard (if enabled), Overload (if LSS
enabled), and as a horn.
DESCENT - Vehicle alarm will function for Arm Guard (if enabled), Overload (if LSS
enabled), as a horn and during Lift Down motion.
MOTION - Vehicle alarm will function for Arm Guard (if enabled), Overload (if LSS
enabled), as a horn and during Drive and Lift motion.
NOT INSTALLED – Load Sensing System (LSS) is not fitted to the vehicle
CUTOUT PLT – Load Sensing System (LSS) is fitted, and Platform Controls are prevented
in the event of an Overload. Ground Controls remain functional. This is the default set-
ting for CE machines.
CUTOUT ALL – Load Sensing System (LSS) is fitted. Platform and Ground Controls are
prevented in the event of an Overload.
PEERLESS - Vehicle is fitted with Peerless drive motors.
ADVANCED DC - Vehicle is fitted with Advanced DC drive motors.
0=NOT INSTALLED – Vehicle is not fitted with an Elevation Prox Sensor. Vehicle has Left
& Right Brake Release Outputs, and Maintained Brake Release functionality.
1=INSTALLED – Vehicle is fitted with an Elevation Prox Sensor (original ES-Series).
Vehicle has a single Brake Release Output, and Momentary Brake Release functionality.
0=FLOODED – Batteries are conventional lead-acid type.
1=AGM – Batteries are absorbed glass mat type.
NO - Vehicle is not fitted with a footswitch
YES - Vehicle is fitted with a footswitch
ality settings first and then changing the model
number of the machine configuration will cause the
personality settings to return to default.
Shaded entries are not available for the selected
market.
Description
– JLG Lift –
SECTION 7 - JLG CONTROL SYSTEM
Model Default Setting per Market
0
1
2
0
0
0
0
0
0
1
1
1
0
0
0
0
0
0
2
2
2
o
1
0
1
1
1
0
0
0
0
0
0
0
0
0
3
4
5
0
0
0
0
0
0
0
1
1
0
0
0
0
0
0
0
2
2
1
0
1
1
1
1
0
0
0
0
0
0
0
0
1
7-9

Advertisement

Table of Contents
loading

Table of Contents