Ethernet (LAN) Port

The rear panel LAN connector (see
connected to an Ethernet LAN or WAN. Communications between the SSP 200 and
the controlling device is via an SSH client using port 22023. The SIS commands and the
actions of the SSP 200 are identical to the commands and actions the processor has when
communicating with it via RS‑232.
By default, Telnet communication on TCP port 23 is disabled on the SSP 200. You can use
Telnet by setting the port using Dataviewer (see
SIS commands (see
LAN port defaults:
DHCP:
SSP 200 IP address:
Subnet mask:
Gateway IP address:
Ethernet Connection
The Ethernet cable can be terminated as a straight‑through cable or a crossover cable
and must be properly terminated for your application (see
Ethernet connector pin assignment).
Crossover cable — Direct connection between the computer and the SSP.
Patch (straight) cable — Connection of the SSP to an Ethernet LAN.
Establish a network connection to a SSP 200 processor via an SSH client:
1.
Download the SSH client software.
2.
Open the SSH software.
3.
Enter the IP address of the SSP 200 in the Host Name or IP address field.
NOTE: If the local system administrators have not changed the value, the default IP
address is 192.168.254.254.
4.
Enter 22023 in the Port field.
5.
The SSP 200 is password protected, so the appropriate administrator or user name and
password must be entered.
a.
Enter admin or user.
b.
Enter the password next to the Password prompt).
NOTES:
The SSP 200 is shipped password‑protected. The factory configured
passwords for all accounts on this device have been set to the device serial
number
In the event of a complete system reset, the passwords convert to the default,
which is extron. New passwords must be configured to secure the device.
figure 3
Set Telnet port map
off
192.168.254.254
255.255.0.0
0.0.0.0
If the login and password are correct, the device responds with a copyright
message including the copyright year, the name of the product, firmware
version, part number, and the current date and time.
If the login and password are incorrect, the login prompt returns. Enter the
administrator or user name and password again.
on page 6) on the device can be
Connection Options
on page 71).
figure 7
on page 8 for the
SSP 200 • SIS Configuration and Control