SIS Configuration
and Control
This section describes Simple Instruction Set (SIS) command programming and control of
the SSP 200, including:
•
•
•
•
Connection Options
The SSP 200 can be configured and controlled using SIS commands or internal web pages.
Configure and control the SSP 200 remotely via a host computer or other device (such as
a control system) by connecting to the rear panel RS‑232 port, LAN port, or the front panel
USB Config port of the SSP device.
RS-232 Port
The SSP 200 has a rear panel serial port (see
connected to a host device such as a computer running the Extron DataViewer utility. The
port makes serial control of the SSP possible. Use the protocol information listed below to
make the connection (see
RS-232 protocol defaults:
•
•
Front Panel Configuration Port
The USB mini‑B port is located on the front panel (see
a host computer for configuration using SIS commands with DataViewer, available at
www.extron.com. To connect the SSP 200 to a host computer, download the USB driver,
follow the on‑screen instructions, and configure the SSP as required.
Connection Options
Host-to-device Communications
Using the Command and Response Tables
Command and Response Tables
Host-to-device Communications
9600 baud
•
no parity
8 data bits
•
no flow control
figure 3
on page 6) that can be
on page 64).
•
1 stop bit
figure 10
on page 11). Connect to
SSP 200 • SIS Configuration and Control
62