P.30
A : For model EV-SA20-2 (1Phase 200V)
Use the power cable with ground. Insert the power cable in the grounding power outlet.
Do not use the power cable adapter.
Fig. 3.1 shows details of the front panel of model EV-SA20-2.
Connect the power connector for the main power supply (1Phase, 200-240V±10% and 50/60Hz).
The power connector type is "IEC 60320-C20". Fig. 3.2 shows the pin assignment of the power
cable. Table 3.1 shows the receptacle and plug specifications.
L
Fig. 3.2 Power Supply Receptacle
(As seen from connecting side)
PM10U
WARNING
Power connector
: IEC 60320-C20
Fig. 3.1 Details of the front panel of model "EV-SA20-2"
The connector type of the power cable is "IEC 60320-C19".
Use the power cable which suits "IEC 60320-C19".
Transit overvoltage on power supply : Installation category 2 of "IEC 60364-4-443".
GND
N
Control connector
: D-sub 15Pin (Female)
Table 3.1 Receptacle and Plug
Receptacle type
Recep. Manufacture
Recommended adapted
plug type
Suitable wire
Power capacity [kVA]
Circuit protector
specifications
PX0596/63
BULGIN
PX0599
AWG #14
3.0
EBARA
CORPORATION