Danfoss VLT 5000 Series Instruction Manual page 123

Hide thumbs Also See for VLT 5000 Series:
Table of Contents

Advertisement

0-f
0-20 mA and
MAX
0-f
4-20 mA and
MAX
0-f
0-32000 p, an output signal proportional to
MAX
the output frequency range in the range 0 - f
rameter 202).
Ref
- Ref
0-20 mA and
MIN
MAX
Ref
- Ref
4-20 mA and
MIN
MAX
Ref
- Ref
0-32000 p, an output signal propor-
MIN
MAX
tional to the reference value in the interval Ref
Ref
(parameters 204/205) is obtained.
MAX
B
-FB
0-20 mA and
MIN
MAX
FB
-FB
4-20 mA and
MIN
MAX
FB
-FB
0-32000 p, an output signal propor-
MIN
MAX
tional to the feedback value in the interval FB
FB
(parameters 414/415) is obtained.
MAX
0 - I
0-20 mA or
VLT, MAX
0 - I
4-20 mA and
VLT, MAX
0 - I
0-32000 p, an output signal proportional
VLT, MAX
to the output current in the interval 0 - I
tained. I
depends on the settings in parameter
VLT,MAX
101 and 103 and can be seen from the Technical da-
ta (I
(60 s).
VLT,MAX
0 - M
0-20 mA and
LIM
0 - M
4-20 mA and
LIM
0 - M
0-32000 p, an output proportional to the
LIM
output torque in the interval 0 - T
obtained. 20 mA corresponds to the value set in pa-
rameter 221.
0 - M
0-20 mA and
NOM
0 - M
4-20 mA and
NOM
0 - M
0-32000 p, an output signal proportional to
NOM
the output torque of the motor. 20 mA corresponds to
the rated torque for the motor.
0 - P
0-20 mA and
NOM
0 - P
4-20 mA and
NOM
0 - P
0-32000 p, 0 - P
NOM
signal proportional to the rated motor output is ob-
tained. 20 mA corresponds to the value set in param-
eter 102.
0 - SyncRPM
0-20 mA and
0 - SyncRPM
4-20 mA and
0 - SyncRPM
0-32000 p, an output signal propor-
tional to the synchronous motor RPM is obtained.
0 - RPM at F
0-20 mA and
MAX
0 - RPM at F
4-20 mA and
MAX
= factory setting, () = display text, [] = value for use in communication via serial communication port
120
(pa-
MAX
-
MIN
-
MIN
is ob-
VLT,MAX
(parameter 221) is
LIM
0-32000 p, an output
NOM
®
VLT
5000 Series
0 - RPM at F
0-32000 p, n output signal propor-
MAX
tional to the synchronous motor RPM at F
eter 202) is obtained.
320
Terminal 42, output, pulse scaling
(AO 42 PULS SCALE)
Value:
1 - 32000 Hz
Function:
This parameter allows scaling of the pulse output sig-
nal.
Description of choice:
Set the desired value.
321
Terminal 45, output
(AO 45 FUNCT.)
Value:
See description for parameter 319.
Function:
This output can function both as a digital and an analog
output. Used as a digital output (data value [0]-[35]) it
generates a 24 V (max. 40 mA) signal; on the analog
outputs (data value [36]-[59]) there is a choice of 0-20
mA, 4-20 mA or a scalable pulse output.
Description of choice:
See description for parameter 319.
MG.51.C5.22 - VLT