AC line supply 3 x 525-690 V
According to international requirements
Normal overload torque (110 %):
Output current
Output
Typical shaft output
High overload torque (160 %):
Output current
Output
Typical shaft output
Max. cable cross-section
to motor
Max. cable cross-section
to load sharing and brake
Normal overload torque (110 %):
Rated input current
High overload torque (160 %):
Rated input current
Max. cable cross-section
power supply
Max. pre-fuses (line) [-]/
UL
Efficiency
Power loss
Weight
Weight
Weight
Enclosure
1. For type of fuse, see section Fuses.
2. American Wire Gauge.
3. Measured using 100 ft [30 m] shielded motor cables at rated load and rated frequency.
4. Max. cable cross-section is the maximum possible cable cross-section allowed to be fitted on the terminals. Always comply with
national and local regulations on min. cable cross-section.
5. Weight without shipping container.
6. Connection bolt power supply and motor: M10; Brake and load sharing: M8
32
I
[A] (525-550 V) 162
VLT,N
I
VLT, MAX
(525-550 V)
I
[A] (551-690 V) 155
VLT,N
I
VLT, MAX
(551-690 V)
S
[kVA] (550 V) 154
VLT,N
S
[kVA] (575 V) 154
VLT,N
S
[kVA] (690 V) 185
VLT,N
[kW] (550 V) 110
[HP] (575 V) 150
[kW] (690 V) 132
I
[A] (525-550 V) 137
VLT,N
I
VLT, MAX
(525-550 V)
I
[A] (551-690 V) 131
VLT,N
I
VLT, MAX
(551-690 V)
S
[kVA] (550 V) 131
VLT,N
S
[kVA] (575 V) 130
VLT,N
S
[kVA] (690 V) 157
VLT,N
[kW] (550 V) 90
[HP] (575 V) 125
[kW] (690 V) 110
I
[A] (550 V) 158
L,N
I
[A] (575 V) 151
L,N
I
[A] (690 V) 155
L,N
I
[A] (550 V) 130
L,N
I
[A] (575 V) 124
L,N
I
[A] (690 V) 128
L,N
3
Normal overload [W] 3114
High overload [W] 2664
IP 21/NEMA 1 [kg] 96
IP 54/NEMA 12 [kg] 96
IP 00, IP 21/NEMA 1 and IP 54/NEMA 12
®
VLT
5000 Series
VLT type 5122
5152
5202
201
253
(60 s) [A]
178
221
278
192
242
(60 s) [A]
171
211
266
191
241
191
241
229
289
132
160
200
250
160
200
162
201
(60 s) [A]
206
243
302
155
192
(60 s) [A]
197
233
288
154
191
154
191
185
229
110
132
150
200
132
160
2
4,6
[mm
]
2 x 70
2,4,6
2 x 2/0
[AWG]
2
4,6
[mm
]
2 x 70
2,4,6
2 x 2/0
[AWG]
198
245
189
234
197
240
158
198
151
189
155
197
2
4,6
[mm
]
2 x 70
2,4,6
2 x 2/0
[AWG]
1
315
350
350
[A]
0,98
3612
4292
2952
3451
IP 00 [kg] 82
91
112
104
125
104
125
MG.51.C5.22 - VLT
is a registered Danfoss trademark.
5252
5302
5352
303
360
418
333
396
460
290
344
400
319
378
440
289
343
398
289
343
398
347
411
478
200
250
315
300
350
400
250
315
400
253
303
360
380
455
540
242
290
344
363
435
516
241
289
343
241
289
343
289
347
411
160
200
250
250
300
350
200
250
315
2 x 185
2 x 350 mcm
2 x 185
2 x 350 mcm
299
355
408
286
339
390
296
352
400
245
299
355
234
286
339
240
296
352
2 x 185
2 x 350 mcm
400
500
550
5155
5821
6149
4275
4875
5185
123
138
151
136
151
165
136
151
165
Need help?