Danfoss VLT 5000 Series Instruction Manual page 121

Hide thumbs Also See for VLT 5000 Series:
Table of Contents

Advertisement

Outputs
Value:
0-100 Hz
0-20 mA
0-100 Hz
4-20 mA
0-100 Hz
0-32000 p
0 - f
0-20 mA
MAX
0 - f
4-20 mA
MAX
0 - f
0-32000 p
MAX
Ref
- Ref
0-20 mA
MIN
MAX
Ref
- Ref
4-20 mA
MIN
MAX
Ref
- Ref
0-32000 p
MIN
MAX
FB
- FB
0-20 mA
MIN
MAX
FB
- FB
4-20 mA
MIN
MAX
FB
- FB
0-32000 p
MIN
MAX
0 - I
0-20 mA
MAX
0 - I
4-20 mA
MAX
0 - I
0-32000 p
MAX
0 - T
0-20 mA
LIM
0 - T
4-20 mA
LIM
0 - T
0-32000 p
LIM
0 - T
0-20 mA
NOM
0 - T
4-20 mA
NOM
0 - T
0-32000 p
NOM
0 - P
0-20 mA
NOM
0 - P
4-20 mA
NOM
0 - P
0-32000 p
NOM
0 - SyncRPM
0-20 mA
0 -SyncRPM
4-20 mA
0 - SyncRPM
0-32000 p
0 - RPM at FMAX
0-20 mA
0 - RPM at FMAX
4-20 mA
0 - RPM at FMAX
0-32000 p
319
Terminal 42, output
(AO 42 FUNCT.)
Function:
This output can act both as a digital and an analogue
output. If used as a digital output (data value [0]-[65]),
a 24 V DC signal is transmitted; if used as an analogue
output either a 0-20 mA signal, a 4-20 mA signal or a
pulse output is transmitted.
Description of choice:
Control ready, the frequency converter is ready for use;
the control card receives supply voltage.
Ready signal, the frequency converter control card is
receiving a supply signal and the frequency converter
is ready for operation.
= factory setting, () = display text, [] = value for use in communication via serial communication port
118
terminal no.
parameter
(0-100 Hz = 0-20 mA)
(0-100 Hz = 4-20 mA)
(0-100 Hz = 0-32000P)
(0-FMAX = 0-20 mA)
(0-FMAX = 4-20 mA)
(0-FMAX = 0-32000P)
(REF MIN-MAX = 0-20 mA)
(REF MIN-MAX = 4-20 mA)
(REF MIN-MAX = 0-32000P)
(FB MIN-MAX = 0-20 mA)
(FB MIN-MAX = 4-20 mA)
(FB MIN-MAX = 0-32000P)
(0-IMAX = 0-20 mA)
(0-IMAX = 4-20 mA)
(0-IMAX = 0-32000P)
(0-TLIM = 0-20 mA)
(0-TLIM = 4-20 mA)
(0-TLIM = 0-32000P)
(0-TNOM = 0-20 mA)
(0-TNOM = 4-20 mA)
(0-TNOM = 0-32000P)
(0-PNOM = 0-20 mA)
(0-PNOM = 4-20 mA)
(0-PNOM = 0-32000P)
(0-SYNCRPM = 0-20 mA)
(0-SYNCRPM = 4-20 mA)
(0-0-SYNCRPM = 0-32000 p)
(0-RPMFMAX = 0-20 mA)
(0-RPMFMAX = 4-20 mA)
(0-RPMFMAX = 0-32000 p)
Ready, remote control, the frequency converter control
card is receiving a supply signal and parameter 002
has been set to remote control.
Enable, no warning, the frequency converter is ready
for use; no start or stop command has been given
(start/disable). No warning.
Running is active when there is a start command or the
output frequency is above 0.1 Hz. Is also active during
ramp down.
Running, no warning , the output frequency is higher
than the frequency set in parameter 123. A start com-
mand has been given. No warning.
Runs in range, no warning, runs within the programmed
current/frequency ranges set in parameters 223-226.
MG.51.C5.22 - VLT
®
VLT
5000 Series
42
45
01(relay) 04 (relay)
319
321
323
[36]
[36]
[37]
[37]
[38]
[38]
[39]
[39]
[40]
[40]
[41]
[41]
[42]
[42]
[43]
[43]
[44]
[44]
[45]
[45]
[46]
[46]
[47]
[47]
[48]
[48]
[49]
[49]
[50]
[50]
[51]
[51]
[52]
[52]
[53]
[53]
[54]
[54]
[55]
[55]
[56]
[56]
[57]
[57]
[58]
[58]
[59]
[59]
[60]
[60]
[61]
[61]
[62]
[62]
[63]
[63]
[64]
[64]
[65]
[65]
is a registered Danfoss trademark.
326

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT 5000 Series and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF