File-Based Zoning - Western Digital Ultrastar Data60 User Manual

Hide thumbs Also See for Ultrastar Data60:
Table of Contents

Advertisement

User Guide
9:0:1295:0
end_device-9:44:10
9:0:1296:0
end_device-9:44:11
b. Issue the following command to access a single host's SMP Discover output:
smp_discover_list /dev/bsg/expander-9:39
c. Zone groups will not be visible due to zoning being disabled. All hosts will have access to
all drives.
d. Issue the following command to access all hosts smp_discover_list:
smp_discover_list --ignore /dev/bsg/expander-9:39
4.6.8   File-Based Zoning
File-based zoning—introduced with firmware 2030—is a method of configuring zoning on an enclosure
using a binary configuration file provided by Western Digital Engineering. The file is downloaded to
the enclosure, and the zoning configuration is stored on the baseboard, where it both enables the file-
based zoning feature and configures the default zoning of the enclousre. Any newly installed IOM will then
automatically use the zoning configuration stored on the baseboard.
Caution: If zoning is later reconfigured using another standard method (i.e. OOBM,
sg_senddiag, SMP, WDDCS Tool), that configuration will only last until the enclousre is power-
cycled or reset. Once rebooted, the enclosure will read and enable the default configuration
from its baseboard. This behavior will continue as long as the file-based zoning feature is
enabled.
Zoning Files
Zoning files are available through the Western Digital Enterprise Support Center
Support/s/) for each of the predefined zoning configurations described in
Configurations (page 180)
(page 202)
below. To request a custom zoning configuration file, please open a support case through the
Western Digital Enterprise Support Center.
Disabling File-Based Zoning
File-based zoning can be disabled at any time by following the instructions in
Zoning Using Linux (page 205)
file-based zoning" may mean one of two distinct options, both of which are available to the user and
described in the disabling procedures:
• Disabling zoning using the file-based feature – This involves downloading and activating a binary file
(
Disable_Config.bin
while keeping the file-based zoning feature enabled.
9:0:1376:0
9:0:1388:0
end_device-9:44:7
9:0:1377:0
9:0:1389:0
end_device-9:44:8
Note: Repeat this substep for all expanders.
as well as the disabling options described in
or
Disabling File-Based Zoning Using Windows (page
) that sets the enclosure zoning to configuration 0, thereby "disabling" zoning
end_device-9:41:24
end_device-9:41:25
(https:/ /portal.wdc.com/
Predefined Zoning
Disabling File-Based Zoning
Disabling File-Based
4. Management
4.6 Zoning
211). "Disabling
202

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H4060-j

Table of Contents