User Guide
Step 5 : Once the download is complete, type:
sg_ses_microcode <dev> -m 0xf
Step 6 : Press Enter.
The IOMs will reset in a staggered manner. This process can take up to 5 minutes to activate.
Step 7 : Ensure multi-pathing can see all of the expected drives.
a. Execute the following command to verify that there are two paths to each drive:
multipath -ll | findstr -i "active ready running" -c
Step 8 : Ensure Windows MPIO can see all paths to the drives after activating IOM A.
a. Execute the following command:
C:\mpclaim.exe –v C:\Users\Administrator\Desktop\mpclaim_output.txt
b. Verify there are two paths to each drive by issuing the following command:
C:\more C:\Users\Administrator\Desktop\mpclaim_output.txt
c. Verify that the output from the mpclaim_output.txt output appears similar to the following
example.
0000000077010524 Active/Optimized 001|005|036|000 0 Adapter: Avago
Adapter, SAS3 3008 Fury -StorPo... (B|D|F:
134|000|000) Controller: 46616B65436F6E74726F6C6C6572 (State: Active)
0000000077000431 Active/Optimized 000|004|049|000 0 Adapter: Avago
Adapter, SAS3 3008 Fury -StorPo... (B|D|F:
132|000|000) Controller: 46616B65436F6E74726F6C6C6572 (State: Active)
MPIO Disk98: 02 Paths, Least Blocks, ALUA Not Supported SN:
5000CCA2532558CC
Supported Load Balance Policies: FOO RR RRWS LQD WP LB Path ID
State SCSI
sg_ses 0 -p 0xe
HGST
H4060-J
2040
Download microcode status diagnostic page:
number of secondary subenclosures: 0
generation code: 0x0
subenclosure identifier: 0 [primary]
download microcode status: Complete, no error, start after
hard reset or power cycle [0x11]
download microcode additional status: 0x0
download microcode maximum size: 1703914 bytes
download microcode expected buffer id: 0x0
download microcode expected buffer id offset: 0
Note: It could take the OS several minutes to rebuild all the paths to the
drives depending on the workload on the drives and how busy the host is.
Multipathing may have to be verified several times to ensure that all paths are
in an optimal state following the reset of IOM A.