Tool Digital Outputs - Universal Robots UR3/CB3 Original Instructions Manual

Hide thumbs Also See for UR3/CB3:
Table of Contents

Advertisement

The internal power supply can be set to either 0V, 12V or 24V at the I/O tab the GUI, see part II.
The electrical specifications are shown below:
Note: *It is highly recommended to use a protective diode for inductive loads
The following sections describe the different I/O's of the tool.

5.4.1 Tool Digital Outputs

The digital outputs are implemented as NPN. When a digital output is activated the corresponding
connection is driven to GND, and when it is deactivated the corresponding connection is open
(open-collector/open-drain). The electrical specifications are shown below:
UR3/CB3
Color
Red
Gray
0V/+12V/+24V (POWER)
Blue
Pink
Yellow
Green
White
Brown
Parameter
Supply voltage in 24V mode
Supply voltage in 12V mode
Supply current in both modes*
DANGER:
1. Connect tools and grippers such that an interruption of power
does not create any hazards, e.g., a work-piece falling out of the
tool.
2. Take care when using 12V, since an error made by the program-
mer can cause the voltage to change to 24V, which might dam-
age the equipment and cause a fire.
NOTE:
The tool flange is connected to GND (same as the red wire).
Signal
0V (GND)
Tool output 0 (TO0)
Tool output 1 (TO1)
Tool input 0 (TI0)
Tool input 1 (TI1)
Analog input 2 (AI2)
Analog input 3 (AI3)
Min
Typ
-
24
-
12
-
-
I-42
5.4 Tool I/O
Max
Unit
-
V
-
V
600
mA
Version 3.10