Figure 2.2: The green area below the ramp is the allowed speeds for a joint during braking. At time 0 an
event (emergency stop or safeguard stop) is detected at the safety processor. Deceleration begins after 24 ms.
3. If a joint is at rest (joint speed is less than 0.2
than 0.05 rad from the position it had when the speed was measured below 0.2
Additionally, for a Stop Category 1, the safety system monitors that after the robot arm is at rest,
the powering off is finalized within 600 ms. Furthermore, after a Safeguard Stop input, the robot
arm is only allowed to start moving again after a positive edge on the safeguard reset input occurs.
If any of the above properties are not satisfied, the safety system issues a Stop Category 0.
A transition to Reduced mode triggered by the reduced mode input is monitored as follows:
1. The safety system accepts both Normal and Reduced mode limit sets for 500 ms after the reduced
mode input is triggered.
2. After 500 ms, only the Reduced mode limits are in effect.
If any of the above properties are not satisfied, the safety system issues a Stop Category 0.
A Stop Category 0 is performed by the safety system with the performance described in the fol-
lowing table. The worst-case reaction time is the time to stop and to de-energize (discharge to an
electrical potential below 7.3 V) a robot running at full speed and payload.
Safety Input Function
Robot Emergency Stop
Emergency Stop Button
System Emergency Stop
Safeguard Stop

2.5.2 Safety-related Electrical Outputs

The table below gives an overview of the safety-related electrical outputs:
UR3/CB3
[rad/s]
Max joint
speed in
normal
mode
0.024
Detection
Time
250 ms
250 ms
250 ms
250 ms
2.5 Safety-related Electrical Interfaces
0.524
rad
/
), it is monitored that it does not move more
s
Worst Case
De-energizing
Time
1000 ms
1000 ms
1000 ms
1000 ms
I-18
time
[s]
rad
/
.
s
Reaction Time
1250 ms
1250 ms
1250 ms
1250 ms
Version 3.10