Faults, Minor Faults, Alarms, And Error Codes Listed Alphabetically - YASKAWA HV600 Installation & Startup

Ac drive bypass for hvac fan and pump applications
Hide thumbs Also See for HV600:
Table of Contents

Advertisement

5.3
Faults, Minor Faults, Alarms, and Error Codes Listed
Alphabetically
Table 5.2
shows the possible fault, minor fault, alarm, and error codes.
The display codes are in alphabetical order. Search the table for the code shown on the keypad, and identify its causes
and possible solutions.
Drive Faults thrown by the HV600 drive will stop the bypass from running the drive but will not stop it from running
in Bypass Mode.
System Faults will stop the drive and also keep it from running in Bypass Mode.
Note:
The number in parentheses adjacent to the code in the table identifies the fault code or minor fault code (hex. number) that was read during
MEMOBUS/Modbus communications.
Example: AFBL (00A2)
Display (Hex.)
AFBL (00A2)
Analog Fbk Lost, Switched to Net
AL02 (00B2)
Interlock Open
AL03 (00B3)
Emergency Override Bypass
AL09 (00B9)
Restart Delay Active
AL13 (00BD)
Loss of Load Detected
AL16 (00C0)
Input Phase Rotation
AL17 (00C1)
Remote Xfer disabled in Reverse
AL18 (00C2)
Auto Xfer disabled in Reverse
AuDis (00A3)
Low PI Aux Fdbk Drive Disabled
AuFbl (00A5)
PI Aux Fdbk Lost Switched to Net
AUXFB (00A4)
PI Aux Feedback Level Loss
AUXFB (0420)
PI Aux Feedback Level Loss
bAT (0085)
Keypad Battery Low Voltage
bAT (0402)
Keypad Battery Low Voltage
bb (0008)
Baseblock
bCE (0416)
Bluetooth Communication Fault
bCE (008A)
Bluetooth Communication Error
BuDif (00A6)
Main Fdbk Lost, Using Diff Fdbk
Bu-Fb (0090)
Main Fdbk Lost Using Backup Fdbk
BuFbl (0091)
Backup Fdbk Lost Chk/Repl Xducer
bUS (0015)
Option Communication Error
bUS (0022)
Option Communication Error
bUSy
Busy
CALL (001D)
Serial Comm Transmission Error
CE (0092)
Run at H5-34 (CE Go-To-Freq)
CE (0014)
Modbus Communication Error
CE (0021)
Modbus Communication Error
CoF (0046)
Current Offset Fault
CPF00 (0081)
Control Circuit Error
CPF01 (0082)
Control Circuit Error
YASKAWA TOEPYAIH6B01A HV600 AC Drive Narrow Bypass Installation & Startup

5.3 Faults, Minor Faults, Alarms, and Error Codes Listed Alphabetically

Table 5.2 List of Fault, Minor Fault, Alarm, and Error Codes
Name
ALM LED
Type
Flashing
Alarm
Flashing
Alarm
Flashing
Alarm
Flashing
Alarm
Flashing
Alarm
Flashing
Alarm
Flashing
Alarm
Flashing
Alarm
Flashing
Alarm
Flashing
Alarm
Flashing
Alarm
Illuminated
Drive Fault
Flashing
Alarm
Illuminated
Drive Fault
Flashing
Alarm
Illuminated
Drive Fault
Flashing
Alarm
Flashing
Alarm
Flashing
Alarm
Flashing
Alarm
Flashing
Alarm
Illuminated
Drive Fault
-
Not an alarm.
Flashing
Alarm
Flashing
Alarm
Flashing
Alarm
Illuminated
Drive Fault
Illuminated
Drive Fault
Illuminated
Drive Fault
Illuminated
Drive Fault
Ref.
130
130
130
130
130
130
130
130
130
130
130
106
130
106
131
106
131
131
131
131
131
5
106
132
132
132
132
106
107
107
107
93