YASKAWA HV600 Installation & Startup page 245

Ac drive bypass for hvac fan and pump applications
Hide thumbs Also See for HV600:
Table of Contents

Advertisement

No.
Name
(Hex.)
Z1-50
Bypass Input Phase Loss
Level
(85F7)
Z1-51
Bypass Input Phase Loss
Delay
(85F8)
Z1-52
Input Phase Rotation
Detection
(85F9)
Z1-53
Load Verify Detection
(85FA)
Z1-55
Welded Contactor Detection Enables and disables detection of K3 "welded contactor" condition.
(85FC)
Z1-56
Test Mode
(85FD)
RUN
Z1-60
Blackout Operation Select
(8601)
Z1-61
Power Loss Restart Delay
Time
(8602)
Z1-70
Green Contactor Mode
(860B)
Z1-98
Minimum Drive SW Ver
(8627)
Expert
Z1-99
Maximum Drive SW Ver
(8628)
Expert
Z2: Bypass Control Input/Output
No.
Name
(Hex.)
Z2-01
Digital Input 1 Function
(TB2-1)
(8563)
Z2-02
Digital Input 2 Function
(TB2-2)
(8564)
Z2-03
Digital Input 3 Function
(TB2-3)
(8565)
Z2-04
Digital Input 4 Function
(TB2-4)
(8566)
Z2-05
Digital Input 5 Function
(TB2-5)
(8567)
Z2-06
Digital Input 6 Function
(TB2-6)
(8568)
Z2-07
Digital Input 7 Function
(TB2-7)
(8569)
YASKAWA TOEPYAIH6B01A HV600 AC Drive Narrow Bypass Installation & Startup
The bypass measures the current unbalance between phases to detect input phase loss.
Sets the current level between phases in Bypass Mode.
Usually it is not necessary to change this parameter.
Sets the trip time for an input phase loss condition in Bypass Mode.
Note:
When you set this parameter to 0.0, it will disable bypass phase loss detection.
Sets bypass response when the Bypass Mode phase rotation is incorrect.
0 : Disabled
1 : Alarm
2 : Fault
Enables and disables verification that the motor is running when commanded to run.
0 : Disabled
1 : Enabled
0 : Disabled
1 : Enabled
Note:
When Z1-42 = 1 or 2 [Soft Starter Selection = Installed – Coast To Stop or Installed – Ramp To
Stop], the bypass will automatically disable welded contactor detection.
Sets the behavior of the drive input contactor K1 during Bypass Mode.
0 : Drive Power Off during Bypass
1 : Drive Power On during Bypass
Sets bypass behavior when contactor voltage is less than Z1-19 [Blackout Voltage Level].
0 : Fault
1 : Restart Delay with Speed Search
2 : Restart Delay from Zero Speed
3 : Disabled
Sets the time delay for restart.
Green Contactor Mode opens the output and motor contactors when the bypass unit is idle.
0 : Disabled
1 : Enabled
"WARNING: If these parameters are changed, undesired operation of the bypass system could occur.
These parameters should only be changed under guidance of Yaskawa technical support (1-800-
YASKAWA)."
"WARNING: If these parameters are changed, undesired operation of the bypass system could occur.
These parameters should only be changed under guidance of Yaskawa technical support (1-800-
YASKAWA)."
Sets the function for bypass digital input 1.
Sets the function for bypass digital input 2.
Sets the function for bypass digital input 3.
Sets the function for bypass digital input 4.
Sets the function for bypass digital input 5.
Sets the function for bypass digital input 6.
Sets the function for bypass digital input 7.
Description
Description
7.15 Z: Bypass Parameters
Default
(Range)
25.0%
(5.0 - 50.0%)
5.0 s
(0.0 - 30.0 s)
0
(0 - 2)
0
(0, 1)
0
(0, 1)
0
(0, 1)
1
(0 - 3)
10 s
(1 - 300 s)
0
(0, 1)
01011
00000 - 65535
01011
00000 - 65535
Default
(Range)
21
(0 - 47)
22
(0 - 47)
23
(0 - 47)
24
(0 - 47)
25
(0 - 47)
0
(0 - 47)
0
(0 - 47)
7
245