No.
Name
(Hex.)
o1-43
2nd Monitor Area Selection
(11C3)
RUN
o1-44
2nd Monitor Area Setting
(11C4)
RUN
o1-45
3rd Monitor Area Selection
(11C5)
RUN
o1-46
3rd Monitor Area Setting
(11C6)
RUN
o1-47
Trend Plot 1 Scale Minimum
Value
(11C7)
RUN
o1-48
Trend Plot 1 Scale
Maximum Value
(11C8)
RUN
o1-49
Trend Plot 2 Scale Minimum
Value
(11C9)
RUN
o1-50
Trend Plot 2 Scale
Maximum Value
(11CA)
RUN
o1-51
Trend Plot Time Scale
Setting
(11CB)
RUN
o1-55
Analog Gauge Area
Selection
(11EE)
RUN
o1-56
Analog Gauge Area Setting
(11EF)
RUN
o1-58
Motor Power Unit Selection
(3125)
o1-80
Fault Screen Display
(31BA)
o1-81
Alarm Screen Display
(31BB)
o1-82
Message Screen Display
(31BC)
YASKAWA TOEPYAIH6B01A HV600 AC Drive Narrow Bypass Installation & Startup
Selects the horizontal range used to display the monitor set in o1-25 [Custom Monitor 2] as a bar
graph. This parameter is only available on an HOA keypad.
0 : +/- Area ( - o1-44 ~ o1-44 )
1 : + Area ( 0 ~ o1-44 )
Sets the horizontal axis value used to display the monitor set in o1-25 [Custom Monitor 2] as a bar
graph. This parameter is only available on an HOA keypad.
Sets the horizontal range used to display the monitor set in o1-26 [Custom Monitor 3] as a bar graph.
This parameter is only available on an HOA keypad.
0 : +/- Area ( - o1-46 ~ o1-46 )
1 : + Area ( 0 ~ o1-46 )
Sets the horizontal axis value used to display the monitor set in o1-26 [Custom Monitor 3] as a bar
graph. This parameter is only available on an HOA keypad.
Sets the horizontal axis minimum value used to display the monitor set in o1-24 [Custom Monitor 1]
as a trend plot. This parameter is only available on an HOA keypad.
Sets the horizontal axis maximum value used to display the monitor set in o1-24 [Custom Monitor 1]
as a trend plot. This parameter is only available on an HOA keypad.
Sets the horizontal axis minimum value used to display the monitor set in o1-25 [Custom Monitor 2]
as a trend plot. This parameter is only available on an HOA keypad.
Sets the horizontal axis maximum value used to display the monitor set in o1-25 [Custom Monitor 2]
as a trend plot. This parameter is only available on an HOA keypad.
Sets the time scale (horizontal axis) to display the trend plot. When you change this setting, the drive
automatically adjusts the data sampling time. This parameter is only available on an HOA keypad.
Sets the range used to display the monitor set in o1-24 [Custom Monitor 1] as an analog gauge. This
parameter is only available on an HOA keypad.
0 : +/- Area ( - o1-56 ~ o1-56 )
1 : + Area ( 0 ~ o1-56 )
Sets the value used to display the monitor set in o1-24 [Custom Monitor 1] as an analog meter. This
parameter is only available on an HOA keypad.
Sets the setting unit for parameters that set the motor rated power.
0 : kW
1 : HP
Sets a full-screen display message to show on the keypad when a fault or CPF occurs.
0 : OFF
1 : ON
Sets a full-screen display message to show on the keypad when an alarm occurs.
0 : OFF
1 : ON
Sets a full-screen display message to show on the keypad when a status message is active.
0 : OFF
1 : ON
7.11 o: Keypad-Related Settings
Description
Default
(Range)
0
(0 - 1)
100.0%
(0.0 - 100.0%)
0
(0 - 1)
100.0%
(0.0 - 100.0%)
-100.0%
(-300.0 - +300.0%)
100.0%
(-300.0 - +300.0%)
-100.0%
(-300.0 - +300.0%)
100.0%
(-300.0 - +300.0%)
300 s
(1 - 3600 s)
1
(0, 1)
100.0%
(0.0 - 100.0%)
1
(0, 1)
1
(0, 1)
0
(0, 1)
0
(0, 1)
7
221