Data Flow - Panasonic HG-S Series User Manual

Contact-type digital displacement sensor
Hide thumbs Also See for HG-S Series:
Table of Contents

Advertisement

FUNCTION SETTINGS

5-1-2 Data Flow

For the controllers, up to 15 slave units can be connected per master unit. (When communica-
tion unit consolidated: up to 14 slave units)
Each can perform independent measurements, as well as calculations on measurement values
among controllers.
Functions are executed as indicated in the flow below.
Example: Simultaneous use of the "THICK" (thickness measurement) calculation application selection
and independent measurement when one master unit and two slave units are connected
Data flow of master unit
Head data
Sampling
Response time
Sensor head
measured value
HEAD.V
Controller data
Alarm processing
Lever ratio
Measurement direction
Calibration
Preset
Normal measured value
NORM.V
Calculated value
CALC
Hold (measurement mode)
Judgment value
JUDGE.V
OUT output
*1 When a calculation mode is selected: The number of slave units used in the calculation var-
ies depending on the calculation application selection.
*2 Only appears during calculation.
5-6
Data flow of slave unit 1
Head data
Sampling
Response time
Sensor head
measured value
HEAD.V
Controller data
Alarm processing
Lever ratio
Measurement direction
Calibration
Preset
Normal measured value
NORM.V
Calculation
*1
*2
Judgment value
JUDGE.V
Data flow of slave unit 2
Head data
Sampling
Response time
Sensor head
measured value
HEAD.V
Controller data
Alarm processing
Lever ratio
Measurement direction
Calibration
Preset
Normal measured value
NORM.V
Hold (measurement mode)
Judgment value
JUDGE.V
OUT output
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
Refer to
"5-2-11 Response Time
(
)"
"5-3-9 Alarm Setting
(
)"
"5-2-10 Lever Ratio
(
)"
"5-2-9 Measurement
Direction (
"5-7 Calibration Set-
tings (
)"
"5-2-6 Preset Value
(
)"
"5-4 Calculation Set-
tings (
) (Master
Unit Only)"
"5-3-1 Hold Setting
(
)"
Output HIGH / GO / LOW
judgment as final result of
data processing.
"5-2-12 Output Opera-
tion (
)"
"5-3-4 External Out-
put (
)"
)"