FUNCTION SETTINGS

5-3-1 Hold Setting (

Set the hold method for the judgment value (JUDGE.V).
To output the regular measured value in real-time, set the measurement mode to sample hold
"S-H", and leave the external input OFF.
■ Measurement Modes (
You can select one of the following nine types for the hold mode.
Measurement mode
(MEAS)
Sample hold
(S-H)
Peak hold (P-H)
Bottom hold (B-H)
Peak to peak hold
(P-P)
Peak to peak hold / 2
(P-P/2)
NG hold (NG-H)
Self sample hold
(SLF.S-H)
Self peak hold
(SLF.P-H)
Self bottom hold
(SLF.B-H)
<Reference>
● When the calculation application selection function is set to "STAND" (standard difference), the
hold setting on the master unit is invalid.
● Depending on the calculation application selection setting, the hold setting on the slave unit
used for calculation may be invalid.
5-28
)
)
Function
Perform hold output of judgment value
(JUDGE.V) only when external input is
ON.
When external input is OFF, update judg-
ment value (JUDGE.V) whenever neces-
sary and output. (Real-time output)
Perform hold output of maximum value
as judgment value (JUDGE.V).
Perform hold output of minimum value as
judgment value (JUDGE.V).
Perform hold output of difference be-
tween maximum value and minimum
value as judgment value (JUDGE.V).
Perform hold output of one-half of differ-
ence between maximum value and mini-
mum value as judgment value (JUDGE.
V).
Hold LOW judgment and HIGH judgment
output.
Perform automatic hold
output of judgment value
Delay timer
(JUDGE.V) by self trig-
ger after delay elapses.
Perform automatic hold
output of judgment value
Static width
(JUDGE.V) by self trig-
ger after measurement
fluctuation stabilizes.
Perform automatic hold output by self
trigger of maximum value as judgment
value (JUDGE.V).
Perform automatic hold output by self
trigger of minimum value as judgment
value (JUDGE.V).
External
trigger input
Valid
Valid
Valid
Valid
Valid
Valid
Invalid
(Use self trigger)
Invalid
(Use self trigger)
Invalid
(Use self trigger)
Invalid
(Use self trigger)
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
Section
"Sample Hold"
"Peak Hold, Bottom Hold,
Peak to Peak Hold, Peak
to Peak Hold / 2"
"NG Hold"
"Self Sample Hold (Delay
Timer)"
"Self Sample Hold (Static
Width)"
"Self Peak Hold / Self Bot-
tom Hold"

Advertisement

Table of Contents
loading