Panasonic HG-S Series User Manual page 115

Contact-type digital displacement sensor
Hide thumbs Also See for HG-S Series:
Table of Contents

Advertisement

Self Sample Hold (Delay Timer)
The normal measured value (NORM.V) can be held automatically as the judgment value
(JUDGE.V) when the delay time elapses after the specified self trigger level is exceeded.
Timing chart
HIGH set value
LOW set value
Self trigger
level
ON
TRIG
indicator
OFF
ON
HOLD
indicator
OFF
Outputs OUT1 / OUT2 / OUT3 according to output setting.
1. The previous value is held until the delay time elapses. (When the power is turned ON, the
indeterminate state is held.)
2. After the delay time elapses, the normal measured value (NORM.V) is held as the judgment
value (JUDGE.V) until the next self trigger action.
3. During the delay time, the judgment value (JUDGE.V) is held while all judgment outputs turn
OFF.
4. Before the delay time elapses, an alarm state occurs if the normal measured value (NORM.V)
falls below the self trigger level. (When the self trigger edge direction is "UP".)
5. If the reset input turns ON, the indeterminate state is held. If this occurs during the delay
time, the delay time ends.
6. Judgment output outputs the judgment result based on the output setting.
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
Self trigger level
Delay timer
Hold
Delay timer
interval
Delay timer
Judgment value (JUDGE.V) hold
Hold
Judgment value (JUDGE.V)
Alarm output
Hold
interval
Delay timer
Delay timer
FUNCTION SETTINGS
Normal measured value (NORM.V)*
Delay timer
5-43

Advertisement

Table of Contents
loading

Table of Contents