5-3-7 Scaling Upper Limit Value / Scaling Lower Limit Value (
When analog scaling is set to "FREE", you can set the upper limit value and lower limit value of
scaling.
When scaling lower limit value < scaling upper limit value
●
Analog current output
20mA
4mA
When scaling lower limit value > scaling upper limit value
●
Analog current output
20mA
4mA
When scaling lower limit value = scaling upper limit value
●
Analog current output
20mA
4mA
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
Lower limit value
(0.5mm)
Upper limit value
(0.5mm)
Outputs 4mA.
Lower limit value = Upper limit value
(5mm)
Judgment value (JUDGE.V)
Upper limit value
(5mm)
Judgment value (JUDGE.V)
Lower limit value
(5mm)
Judgment value (JUDGE.V)
FUNCTION SETTINGS
/
)