Setting up General Functions

6.1 Flow of Measurement Data

For controllers, up to 15 slave units can be connected to a master unit. (Up to 14 slave units
can be connected if a communication unit is connected.) Each controller can perform measure-
ments independently and measured values can be calculated between controllers. Each func-
tion is executed as shown in the following flowchart.
Example: When one master unit and two slave units are connected and calculation application
selection "THICK" (thickness/width measurement) and independent measurement are
used at the same time <When the master unit and slave unit 1 perform calculations
and slave unit 2 performs independent measurement>
Data flow of master unit
Sensor head
(Receiver)
Sampling
Alarm processing
Sensor head measured value
HEAD.V
Controller data
Response time
Calibration
Preset
Normal measured value
NORM.V
(Note 2)
Calculated value
CALC
Hold (measurement mode)
Judgment value
JUDGE.V
Judgment output
OUT output
Analog output
Connection commu-
nication output
Notes: 1) When calculation mode is selected, the number of slave units performing calcula-
tions varies according to the calculation application selection settings.
2) Displayed only during calculation
6-2
Data flow of slave unit 1
Sensor head
(Receiver)
Sampling
Alarm processing
Sensor head measured value
HEAD.V
Controller data
Response time
Calibration
Preset
Normal measured value
NORM.V
(Note 1)
Calculation
Judgment value
JUDGE.V
Data flow of slave unit 2
Sensor head
(Receiver)
Sampling
Alarm processing
Sensor head measured value
HEAD.V
Controller data
Response time
Calibration
Preset
Normal measured value
NORM.V
Hold (measurement mode)
Judgment value
JUDGE.V
Judgment output
OUT output
Analog output
Connection commu-
nication output
Reference section
"7.2.12 Sampling Cycle"
"7.2.9 Alarm Settings"
"6.3.3 Average Count
(Response Time)"
"7.6.1 Calibration Selection"
"6.4.6 Preset Value"
"7.3 Calculation Settings
(For Master Units Only)"
"7.2.1 Hold Settings"
Judgment "HIGH", "GO",
or "LOW" is output as the
result at the end of data
processing.
"6.4.10 Output Operation"
"7.2.4 External Outputs"
WUME-HGT-3