7-2 Replacing the Probe

● Always secure the spindle to prevent rotation before replacing the probe. Risk of product
damage if an excessive torque (0.2N·m or more) is applied to the spindle.
● If the rubber bellows is damaged or deformed during probe replacement, the specifica-
tions of the protective structure may not be satisfied.
1.
Turn the probe screw in the direction of the arrow and remove the probe from the spindle.
When turning the probe screw, hold the cut face of the spindle with the provided sensor
head fastening wrench to prevent the spindle from turning.
Hold the sensor head fastening wrench in place, and turn only the probe.
Sensor head fastening
wrench (accessory)
2.
Attach the probe to the spindle.
The tightening torque should be 0.4N·m or less. Make sure that the probe does not come OFF.
When turning the probe screw, hold the cut face of the spindle with the provided sensor
head fastening wrench to prevent the spindle from turning.
Hold the sensor head fastening wrench in place, and turn only the probe.
3.
After attaching the probe, wipe the spindle with absolute alcohol to remove any dirt.