Panasonic HG-S Series User Manual page 144

Contact-type digital displacement sensor
Hide thumbs Also See for HG-S Series:
Table of Contents

Advertisement

FUNCTION SETTINGS
■ Catch Check
If the movement of the spindle worsens due to aging and the spindle does not return complete-
ly, accurate measurement will no longer be possible. This function detects failure of the spindle
to return completely.
The information checked varies depending on whether the type is regular or air-driven.
<Regular type>
While the trigger input is ON, the function checks whether or not the spindle extends out fully
[whether the normal measured value (NORM.V) is lower than the set LOW set value].
If the measured value never drops below the LOW set value while the trigger input is ON, an
alarm occurs.
You can change the settings so that an alarm does not occur.
Judgment value (JUDGE.V)
HIGH set value
LOW set value
<Reference>
This function can only be used when the measurement mode is set to a mode that has external
trigger input enabled in "5-3-1 Hold Setting (
5-72
Normal
Fully extended
Not fully extended
Normal measured value (NORM.V)
)".
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
Abnormal
Judgment value (JUDGE.V)
Catch alarm

Advertisement

Table of Contents
loading

Table of Contents