BASIC OPERATION
<Setting method>
1.
Long-press the UP key for 2 seconds. (The number of lit increments in the circle meter in-
creases.)
2.
"NORM.V" (sensor head measured value) appears in the digital display / SUB (green).
3.
Press the LEFT / RIGHT key to change to the item you want to display.
Note: Calculation function settings are configured on the master unit. When a setting other than "STAND" (stan-
dard difference) is selected for the calculation function, "CALC" appears only on the master unit. When the
"STAND" (standard difference) setting is selected for the calculation function, "CALC" appears on the slave
units but not on the master unit. When the calculation function is not used, this does not appear on either the
master unit or the slave units.
4.
Press the ENTER key to finalize the setting and return to the base screen.
If you press the ENTER key with "LABEL" selected, you will move to the label setting
screen.
4-6
Long-press for 2 seconds
(Note)