3-4 Connecting the Controller and Sensor Head

Connect the controller and the sensor head using the sensor head connection cable CN-HS-C□
/ CN-HS-C□L.

3-4-1 Attaching the Sensor Head and Sensor Head Connection Cable

● After attaching the connector, verify that the connector is firmly tightened.
If loose, the connector may come off and an error will result.
● When attaching the sensor head connection cable to this product, take care not to apply
force to the product.
● The L-shaped CN-HS-C□L connector cannot be connected to an air-driven type.
1.
Insert the sensor head connection cable into the connector for the sensor head connection
cable on the sensor head.
2.
Turn the fastening ring on the sensor head connector in the direction shown and tighten
firmly.
Do not turn the connector on the L-shaped connector CN-HS-C□L.
Risk of damage.