5-3-3 External Input (

You can select from four combinations for the signals that are input into input 1 / input 2 / input 3
of external input.
External input setting combinations are shown below.
External input
Preset / Reset / Trigger (P/R/T )
Bank A / Bank B / Preset (BANK/P)
Bank A / Bank B / Reset (BANK/R)
Bank A / Bank B / Trigger (BANK/T)
Minimum input time
The minimum input time depends on the input type.
<Preset input>
ON
Preset input
OFF
<Reset input>
ON
Reset input
OFF
<Trigger input>
ON
Trigger input
OFF
<Bank A / B input>
Bank
ON
Bank A
OFF
ON
Bank B
OFF
*1: Minimum of 50ms when bank save is set to "ALL".
*2: If more than 8ms elapses, data may be read from bank 1 and then bank 2.
<Reference>
● For controller I/O circuit diagrams, refer to "3-6-2 I/O Circuit Diagrams".
● For input all, refer to "5-3-2 Input All (
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
)
Input 1 (Pink)
Preset
Minimum 20ms
Minimum 20ms
Minimum 2ms Minimum 2ms
Bank 1
20ms (*1)
Minimum 20ms
Input signal combination
Input 2 (Violet)
Preset
Bank A
Bank A
Bank A
Minimum 20ms
Minimum 20ms
Minimum 20ms (*1)
) (Master Unit Only)".
FUNCTION SETTINGS
Input 3 (Pink / Violet)
Reset
Bank B
Bank B
Bank B
Preset release
Minimum 1.5 sec.
Bank 3
20ms (*1)
Maximum 8ms (*2)
Trigger
Preset
Reset
Trigger
5-55