Explanation Of Modes; Display Switching Mode - Panasonic HG-S Series User Manual

Contact-type digital displacement sensor
Hide thumbs Also See for HG-S Series:
Table of Contents

Advertisement

4-2 Explanation of Modes

4-2-1 Display Switching Mode

<Overview>
You can change the display of the digital display / SUB (green) as needed for the task.
Using the display switching function, you can display the actual measured value (spindle posi-
tion) and a judgment value such as a calculation result at the same time for comparison. This
makes it easy to check the state of sensor head measurement.
<Settings>
1. Normal measured value (default value)
6. Sensor head measured value
Name
Normal measured
1
value
Calculated value
2
(Note)
3 Label
4 LOW set value
5 HIGH set value
Sensor head mea-
6
sured value
Note: Calculation function settings are configured on the master unit. When a setting other than "STAND" (stan-
dard difference) is selected for the calculation function, "CALC" appears only on the master unit. When the
"STAND" (standard difference) setting is selected for the calculation function, "CALC" appears on the slave
units but not on the master unit. When the calculation function is not used, this does not appear on either
the master unit or the slave units.
<Reference>
● "HEAD.V" (Head Value) is the measured value (spindle position) from the sensor head.
● "NORM. V" (Normal Value) reflects the preset, measurement direction, lever ratio, and calibra-
tion function.
● The judgment value that appears in the digital display / MAIN (white) triggers judgment output
ON / OFF based on the LOW set value and the HIGH set value. Analog output is also output
based on the judgment value.
For the data flow, refer to "5-1-2 Data Flow".
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
2. Calculated value (Note)
5. HIGH set value
Digital display
SUB (green)
Shows the normal measured value.
• When displayed while using the hold function, you
can check internal measured values that are not held.
Shows the calculated value.
• When displayed while using the calculation function
and hold function, you can check calculation results
that are not held.
You can view and set any values or characters.
• This saves you the trouble of attaching sensor num-
ber and other labels on the controller.
Shows the LOW set value.
• You can check the judgment value and lower limit
value at the same time.
Shows the HIGH set value.
• You can check the judgment value and upper limit
value at the same time.
Shows the measured value (spindle position) from the
sensor head.
• You can display this while using a preset or the cali-
bration function to check the actual pre-correction
measured value (spindle position).
BASIC OPERATION
3. Label
4. LOW set value
Description
Factory
default state
Default state
4-5

Advertisement

Table of Contents
loading

Table of Contents