FUNCTION SETTINGS
<Reference>
● Set the hysteresis to a value that is smaller than the difference between the HIGH set value and
the LOW set value. If the hysteresis is set to a value that is larger than the difference between
the HIGH set value and the LOW set value, a GO judgment will not be output.
● Even when a hysteresis is set, always set a HIGH set value that is higher than the LOW set
value. If the LOW set value is higher than the HIGH set value, a GO judgment will not be output.
Setting method
Long-press for 2 seconds
Setting item
Hysteresis (HYSTER)
5-14
HIGH set value
LOW set value
Judgment value
HIGH
GO
LOW
LOW set value
HIGH set value
Judgment value
HIGH
GO
LOW
CALC: Only appears on master unit
: Change value
Finalize
0 to 199.9999 (mm)
: Move through digits
Setting range