Panasonic HG-S Series User Manual page 106

Contact-type digital displacement sensor
Hide thumbs Also See for HG-S Series:
Table of Contents

Advertisement

FUNCTION SETTINGS
■Peak to Peak Hold (Trigger mode: Hold)
With respect to normal measured values (NORM.V) during any sampling interval, the difference
between the peak value (maximum value) and the bottom value (minimum value) is held as the
judgment value (JUDGE.V).
Timing chart
HIGH set value
LOW set value
0
ON
TRIG
indicator
OFF
ON
HOLD
indicator
OFF
6
Outputs OUT1 / OUT2 / OUT3 according to output setting.
1. Based on the peak to peak setting (peak value to bottom value), the judgment value (JUDGE.
V) is gradually updated from 0.
2. The judgment value (JUDGE.V) is held while the external trigger input is ON.
3. If the reset input turns ON while the external trigger input is OFF, an indeterminate state oc-
curs during the response time. All outputs remain OFF during an indeterminate state.
4. After the response time elapses, the indeterminate state is released.
5. If the reset input turns ON while the external trigger input is ON, the indeterminate state is
held until the external trigger input turns OFF.
6.
Judgment output outputs the judgment result based on the output setting.
* When the calculation function is used, calculation value "CALC" is shown instead of normal
measured value (NORM.V).
5-34
Normal measured value (NORM.V) *
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
Judgment value
(JUDGE.V)
Indeterminate state is held.

Advertisement

Table of Contents
loading

Table of Contents