Panasonic HG-S Series User Manual page 41

Contact-type digital displacement sensor
Hide thumbs Also See for HG-S Series:
Table of Contents

Advertisement

● HG-SC111-P / PNP output type
AGND
*S1
Non-voltage contact or PNP open collector transistor
+4V to +V DC: Valid
0 to +0.6V DC or open: Invalid
Note: Use shielded wire for the analog output.
<Reference>
● All outlets are equipped with short-circuit protection. If any one of outputs 1 to 3 short-circuits,
all outputs temporarily turn OFF. The outputs automatically recover when the short-circuit state
is cleared.
● The HG-SC111-P cable does not have +V or 0V. Power is supplied from the connector of the
master unit.
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
(Pink) External input 1
(Violet) External input 2
(Pink / Violet) External input 3
(Black) Output 1
(White) Output 2
(Black / Gray) Output 3
(Gray) Analog current output (4 to 20mA)
(Shielded) Analog ground (Note)
or
INSTALLATION AND CONNECTIONS
*S1
*S1
Load
Load
Connect to +V (brown) of
HG-SC101-P
*S1
Load
Connect to 0V (blue) of
HG-SC101-P
Load
(250Ω max.)