3.2 Upper and Lower Limit Value Settings

Set the upper and lower limit values for the judgment of the measured value.
Judgment is made as to the comparison between the value after display
scaling and the upper and lower limit settings. Before entering the upper limit
value, determine the display scale.
If holding measurement is selected, judgment is made as to the held value.
In the calculation mode, the result of calculation is judged.
POINT

3.2.1 Setting the Upper and Lower Limit Value Entry Method

There are the following two methods for entering the upper and lower limit
values used for judgment of the detected value.
Mode
Value entry setting
Detection displacement
setting (teaching)
48
Description of action
The upper or lower limit value can be
entered directly as a digital value.
The detection displacement value is set
directly as an upper or lower limit value.
The object to be detected (workpiece)
can be used to enter the setting.
Operation
Press
in
the
upper/lower limit value
setting mode.
Press and hold
in
the upper/lower limit
value setting mode.

Advertisement

Table of Contents
loading