6-6. Current Value Storage Function

The current incident light intensity value can be stored.
The digital display will quickly
blink to confirm the setting.
Press the
MODE key 5 times.
Turn the Jog switch twice
toward the '
' direction.
Press the
Jog switch.
Turn the Jog switch 4 times
toward the '
' direction.
Press the
Jog switch.
Press the
Jog switch.
Press the
MODE key once.
Press the
MODE key once.
36
1Press the [MODE key] 5 times to select 'PRO mode'.
2Turn the [Jog switch] twice toward the '
select 'PRO2 mode'.
3Press the [Jog switch] to enter the 'display switching' state.
4Turn the [Jog switch] 4 times toward the '
enter the 'current value storage setting' state.
5If the [Jog switch] is pressed, the current 'incident light
intensity' (red) will be displayed.
6If the [Jog switch] is pressed, incident light intensity (red) will
quickly blink on the digital display, and the data will be
stored.
7If the [MODE key] is pressed once, the amplifier will return to
'PRO2 mode'.
8Press the [MODE key] once, the amplifier will return to 'RUN
mode' (normal sensing operation).