Setting Range And Initial Value; Limitation In Sampling Period - Panasonic HL-C1-WL Series User Manual

Ultra high-speed laser displacement sensor (ccd style)
Table of Contents

Advertisement

4-2 Setting Range and Initial Value

The setting ranges and initial values changed for the HL-C1-WL Series from the HL-C1
Series are as follow. 
Function item
Sampling
period
Average
frequency
Upper limit
value
Lower limit
value
Upper limit
hysteresis /
lower limit
hysteresis
Analog output
setting,
5V
value
Analog output
setting,
5V
value
Calibration
shift

4-3 Limitation in Sampling Period

The sampling period of HL-C1C-WL during operation with two sensor heads is
susceptible to a limitation in the data buffering function.
There is no limitation in other than the data buffering function.
There is no limitation in the sampling period during operation with only one sensor
head.
Limitation in shortest sampling period (during operation with two sensor heads)
Shortest sampling period
Data buffering
( 1)  During regular measurement (in non-buffering mode)
( 2)  In buffering mode
CHAPTER 4 DESCRIPTION OF MODIFIED FUNCTIONS
HL-C1 Series
Setting
range
100,144,200,255,
332,498,1000 s
OFF, 2 to
32768 times:
16 steps
+20.0000 mm
999.999 mm
999.9999 mm
0.0000 mm
to 2.0000 mm
+20.0000 mm
999.9999 mm
999.9999 mm
99.9999 mm
4-2
Initial value
Setting
Upper line:
85mm type
Lower line:
50mm type
100,144,200,255,
144 s
332,498,1000 s
OFF, 2 to
64 times
32768 times:
16 steps
999.9999 mm
+5.0000 mm
-20.0000 mm
999.9999 mm
-5.0000 mm
0.0300 mm
0.0000 mm
0.0100 mm
to 2.0000 mm
999.9999 mm
+5.0000 mm
-20.0000 mm
999.9999 mm
-5.0000 mm
0.0000 mm
200.0000 mm
100 s
OFF( 1)
HL-C1-WL Series
Initial value
range
350mm type
100 s
512 times
+200.0000 mm
-200.0000 mm
0.30000 mm
+200.0000 mm
-200.0000 mm
0.0000 mm
144 s
ON( 2)