Device parameter
Brake release delay on
starting
Brake holding time on
stopping
Response to overload -
thermal motor model
Trip class
(DSte/RSte, sDSSTe,
sRSSte in startup mode
≠ direct)
Trip class
(sDSSte/sRSSte in
startup mode = direct)
Recovery time
(sDSSte/sRSSte only)
Motor heating
prewarning limit
Prewarning limit -
remaining time for
tripping
Idle time
Response to
temperature sensor
overload
Temperature sensor
Temperature sensor
monitoring
Response to residual
current detection
Response to current
limit violation
M200D AS-Interface Standard
Manual, 08/2014, A5E02548958A/RS-AA/004
Default setting
0 s
- 2.5 to + 2.5 s
Increment: 0.01 s
0 s
0 to 25 s
Increment: 0.01 s
Trip without restart •
Trip without restart
Trip with restart
Warning
CLASS 10
CLASS 5 (10a)
CLASS 10
CLASS 15
CLASS 20
CLASS OFF
CLASS 10
CLASS 5 (10a)
in startup mode
CLASS 10
= direct
CLASS OFF
CLASS 5 (10a)
in startup mode
≠ direct
90 s
60 to 1,800 s
Increment: 30 s
0% (= deactivated) 0 to 95%
Increment: 5%
0 s (= deactivated) 0 to 500 s
Increment: 1 s
0 s (= deactivated) 0 to 255 s
Increment: 1 s
Trip without restart •
Trip without restart
Trip with restart
Warning
Deactivated
Deactivated
Themoclick
PTC type A
Yes
Yes
No
Trip
Warning
Trip
Warning
Warning
Trip
Setting range
Configuring/assigning parameters
5.4 Assigning parameters
Ext. PI
DS 203
Motor
Starter
ES
117