Chapter 5 Function code
DC Bus voltage control
P23.00
option
Overvoltage stall
P23.01
threshold
P23.02
Undervoltage threshold
P23.03
Overvoltage stall ratio
P23.04
Undervoltage stall ratio
Undervoltage trip
P23.05
threshold
Undervoltage fault
P23.06
detecting time
P23.07
Rapid current limit
Over-speed detection
P23.10
value
P23.11
Over-speed detection time
Detection value of too large
P23.12
speed deviation
Detection value of too large
P23.13
speed deviation
Input phase loss
P23.14
detection time
Output phase loss
P23.15
inbalance detecting
VFD500 high performance vector control frequency inverter user manual

23 Group Drive protection function setting

Unit'digit :Overvoltage stall control

0:overvoltage stall disabled

1:overvoltage stall enabled

2:overvoltage stall enabled self-adjustable
The over-voltage stall function limits the amount of
power generated by the motor by extending the
deceleration time or even increasing the speed,
avoiding over-voltage on the DC side and reporting
over-voltage faults

Ten'unit:Undervoltage stall control

0:undervoltage stall disabled 

1:Undervoltage stall(decelerate to zero
speed and be in standby mode,after
power restoring ,it will run again
automatically)

2: Undervoltage stall
deceleration(decelerate to zero and stop)
The undervoltage stall function reduces the
motor power consumption or reduces the power
consumption of the motor or turns it into a
power generation operation to avoid the
undervoltage fault on the DC side.
The undervoltage stall function is used when the
input power supply quality is poor (the power
supply voltage fluctuates downward or the sporadic
short power is suspended), and it is necessary to
keep the inverter running as much as possible.
220V Level: 320V~400V

380V Level: 540V~800V

480V Level:650V~950V
220V level: 160V~300V

380V level: 350V~520V

480V level: 400V~650V
0~10.0
0~20.0
220V Level:160V~300V

380V Level:350V~520V

480V Level:400V~650V
0.0s~30.0s
0:Disabled

1:Enabled
0.0%~120.0% maximum frequency
0.0s~30.0s0.:shielding
0.0%~100.0%(motor rated frequency)
0.0s~30.0s
0.0:shielding
0.0s~30.0s
0.0:forbidden
0%~100%
86
01
Depend
Depend
1.0
4.0
Depend
1.0s
1
120.0%
1.0s
20.0%
0.0s
8.0s
30%