Chapter 5 Function code
P41.02
When selecting frequency sleep and frequency wake-up, it must be set by P41.01 < P41.02. When the frequency
source is PID setting, and the frequency wake-up must be set to PID shutdown operation: P40.39 = 1.
P41.03
P41.04
P41.05
P41.06
P41.07
r42.00
r42.01
r42.02
P42.03
P42.04
P42.05
VFD500 high performance vector control frequency inverter user manual
Wake up
0.00hz~600.00hz, ,It will wake up if value is
threshold by
bigger than this value
frequency
Sleep setting
value by
0~100.0%
pressure
Wake up
threshold by
0.~100.0%
pressure
Sleep delay time
0.0s~6000.0s
Wake up delay
0.0s~6000.0s
up
Setting value decide by P03.16
P03.16 = 2, 0.00~600.00s;
Sleep
P03.16 = 1, 0.0s~6000.0s;
decelerating
P03.16 = 0, 0s~60000s
time
P41.07 set to 0,sleeping stop mode to free
coast。

42 Group Simple PLC

PLC current
running mode
PLC current
running
remaining time
PLC times of
cycles
Unit'digit:

0: single cycle then stop

1: single cycle then keep last speed

2: recycle

3: Plc reset when single cycle stop
Ten's digit:
0:power off without saving
1:power off with saving

Hundred'digit:

0:stop without saving
Simple PLC
with saving
running mode
0: Restart from the first stage; stop during
running (cause by the stop command, fault
or power loss), run from the first stage after
restart. 1: Continue to run from the stop
frequency; stop during running(cause by
stop command and fault), the inverter
willrecord the running time automatically,
enter into the stage after restart and keep
the remaining running at the setting
frequency.
PLC running
1~60000
times
0.0~6553.5 unit depend on P42.21
PLC step 1
Notice:Running time do not conclude
running time
acceleration and deceleration time,same as
following
Read only
Read only
Read only
1:stop
102
0.00Hz
0.0%
0.0%
0.0s
0.0s
0.00s
-
-
-
003
1
0.0