Parameter Group 15: Drive Information; Drive Identification - Danfoss VLT Micro Drive FC 51 Programming Manual

Hide thumbs Also See for VLT Micro Drive FC 51:
Table of Contents

Advertisement

Parameter Descriptions
®
VLT
Micro Drive FC 51 Programming Guide

4.12 Parameter Group 15: Drive Information

Parameter group containing information on operating
data, hardware configuration, software version, etc.
15-00 Operating Time
Range:
Function:
0 days
*
[0-65535
View how many days the frequency
days]
converter has been powered up.
The value is saved at power off and
cannot be reset.
15-01 Running Hours
Range:
Function:
0
[0- 2147483647] View running hours of motor.
*
The value is saved at power off and can be
reset in 15-07 Reset Running Hours Counter.
15-02 kWh Counter
Range:
Function:
0
[0-65535] View power consumption in kWh as a mean value
over one hour.
Reset counter in 15-06 Reset kWh Counter.
15-03 Power Ups
Range:
Function:
0
[0-2147483647] View number of times frequency converter
has been powered up.
Counter cannot be reset.
15-04 Over Temps
Range:
Function:
0
[0-65535] View number of times frequency converter has
tripped due to over temperature.
Counter cannot be reset.
15-05 Over Volts
Range:
Function:
0
[0-65535] View number of times frequency converter has
*
tripped due to over voltage.
Counter cannot be reset.
15-06 Reset kWh Counter
Option:
Function:
[0]
Do Not Reset
Counter is not reset.
*
[1]
Reset Counter
Counter is reset.
15-07 Reset Running Hours Counter
Option:
Function:
[0]
Do Not Reset
Counter is not reset.
*
[1]
Reset Counter
Counter is reset.
®
MG02C602 - VLT
is a registered Danfoss trademark
RSPSupply - 1-888-532-2706 - www.RSPSupply.com
http://www.RSPSupply.com/p-12769-Danfoss-132F0026-VFD-Micro-Drive-440V-5HP.aspx
4.12.1 15-3* Fault Log
This parameter group contains a fault log showing reasons
for the ten latest trips.
15-30 Fault Log: Error Code
Range:
Function:
0
[0-255] View error code and look it up in VLT Micro Quick
Guide, MG02B.

4.12.2 15-4* Drive Identification

Parameters containing read only information about the
hardware and software configuration of the frequency
converter.
15-40 FC Type
Option:
Function:
View FC type.
15-41 Power Section
Option:
Function:
View power section of frequency converter.
15-42 Voltage
Option:
Function:
View voltage of frequency converter.
15-43 Software Version
Option:
Function:
View software version of frequency converter.
15-46 Frequency Converter Ordering No
Option: Function:
View ordering number for re-ordering frequency
converter in its original configuration.
15-48 LCP ID No
Option:
Function:
View LCP ID number.
15-51 Frequency Converter Serial Number
Option:
Function:
View frequency converter serial number.