Danfoss VFD500 Series Manual page 50

Table of Contents

Advertisement

VFD500 high performance vector control frequency inverter user manual
Function
Parameter name
code
Multiple step speed
P01.20
Rotation direction
Multiple step speed 0/
P01.21
in-built plc 1
Multiple step speed 1/
P01.22
in-built plc 2
Multiplestep speed 2/in-
P01.23
built plc 3
Multiple step speed 3/
P01.24
in-built plc 4
Multiple step speed 4/
P01.25
in-built plc 5
Multiple-step speed 5/
P01.26
in-built plc 6
Multiple step speed 6/
P01.27
in-built plc 7
Multiple step speed 7/
P01.28
in-built plc 8
Multiple step speed 8/
P01.29
in-built plc 9
Multiple step speed 9/
P01.30
in-built plc 10
Multiple step speed 10/
P01.31
in-built plc 11
Multiple step speed 11/
P01.32
in-built plc 12
Multiple step speed 12/
P01.33
in-built plc 13
Multiple step speed 13/
P01.34
in-built plc 14
Multiple step speed 14/
P01.35
in-built plc 15
Multiple step speed 15/
P01.36
in-built plc 16
P01.37
Jog frequency
Jog command when
P01.38
running
P01.39
UP/DOWN rates
Description
Bit0~15 corresponding to 0~15 phase
direction
0:forward direction 1:reverse direction
Lower limit frequency (P01.09)~maximum
frequency(P01.06)Note: When the unit's digit
of P01.19 is set to non-zero, this setting is
invalid.
Lower limit frequency(P01.09)~maximum
frequency(P01.06)
Lower limit frequency(P01.09)~maximum
frequency(P01.06)
Lower limit frequency(P01.09)~maximum
frequency(P01.06)
Lower limit frequency(P01.09)~maximum
frequency(P01.06)
Lower limit frequency(P01.09)~maximum
frequency(P01.06)
Lower limit frequency(P01.09)~maximum
frequency(P01.06)
Lower limit frequency(P01.09)~maximum
frequency(P01.06)
Lower limit frequency(P01.09)~maximum
frequency(P01.06)
Lower limit frequency(P01.09)~maximum
frequency(P01.06)
Lower limit frequency(P01.09)~maximum
frequency(P01.06)
Lower limit frequency(P01.09)~maximum
frequency(P01.06)
Lower limit frequency(P01.09)~maximum
frequency(P01.06)
Lower limit frequency(P01.09)~maximum
frequency(P01.06)
Lower limit frequency(P01.09)~maximum
frequency(P01.06)
Lower limit frequency(P01.09)~maximum
frequency(P01.06)
0.00Hz~maximum frequency(P01.06)
0:not responsive
1:responsive
0.00(auto rates)~600.00Hz/s
47
Chapter 5 function code table
Default
Property
0
0.00Hz
0.00Hz
0.00Hz
0.00Hz
0.00Hz
0.00Hz
0.00Hz
0.00Hz
0.00Hz
0.00Hz
0.00Hz
0.00Hz
0.00Hz
0.00Hz
0.00Hz
0.00Hz
5.00Hz
0
1.00Hz/s

Advertisement

Table of Contents
loading

Table of Contents