Danfoss VFD500 Series Manual page 63

Table of Contents

Advertisement

Chapter 5 Function code
r06.00
DI port status
P06.01
DI1 Numeric input function
P06.02
DI2 Numeric input function
P06.03
DI3 Numeric input function
P06.04
DI4 Numeric input function
DI5(HDI) Numeric input
P06.05
function
DI6 Numeric input
P06.06
function(option card)
DI7 Numeric input
P06.07
function(option card)
VFD500 high performance vector control frequency inverter user manual
06 Group Multi-function Digital input
Bit0~Bit8 Correspond to DI1~DI8
Bit12~Bit15 Correspond to VDI1~VDI4
0:No function
1:FORWARD
2:Reverse/Forward and reverse switchover
3:Three wire control
4:Forward jog command
5:Reverse jog command
6:Terminal UP
7:Terminal DOWN
8:Clear up UP/DOWN offset
9:Coast to stop/free stop
10:Fault reset
11:Reverse forbidden
12:Switching run command to Keypad
13:Switching run command to Communication
14:fast stop
15:external stop
16:Switch between motor 1 and motor 2
17:Pause operatoin
18:DC braking
19:Switch between torque and speed Control
20:Torque control diabled
21:Multi-step speed terminal 1
22:Multi-step speed terminal2
23:Multi-step speedterminal3
24:Multi-step speed terminal4
25:Frequency source switchover
26:Switch main frequency source to Numeric
frequency setting
27:Switch main frequency source to AI1
28:Switch main frequency source to AI2
60
-
1
2
4
10
0
0
0

Advertisement

Table of Contents
loading

Table of Contents